Development and utilization of Web-based open system for CT dose calculator, WAZA-ARIv2

Koba, Yusuke*; Nakada, Yoshihiro*; Matsumoto, Shinnosuke*; Akahane, Keiichi*; Ono, Koji*; Sato, Kaoru; Takahashi, Fumiaki; Endo, Akira; Shimada, Yoshiya*; Kai, Michiaki*

no journal, , 

While CT scan is useful for diagnosis, exposure dose derived from CT scan is relatively high. Therefore, it is important to manage patient doses and to prevent the excess exposures in young patients. JAEA developed the CT dose calculator, WAZA-ARIv2 under the collaboration research project with the National Institute of Radiological Sciences and the Oita University of Nursing and Health Sciences. In WAZA-ARIv2, users can accurately calculate exposure doses through the browser under consideration of patients information about sexes, ages (0y, 1y, 5y, 10y, 15y and adult) and fatness (small, large and extra-large body sizes). The functions of registration and database compilation of CT scan conditions and patient doses are newly added to a WAZA-ARIv2. Users can compare the distribution of patient doses in Japan with those in user's medical institution. Therefore, it will be expected that WAZA-ARIv2 can contribute the management and optimization of patients doses due to CT scan.

Oral presentation

Evaluation of the tube-voltage dependence of organ doses in X-ray CT scans using Monte-Carlo calculation

Koba, Yusuke*; Matsumoto, Shinnosuke*; Nakada, Yoshihiro*; Kasahara, Tetsuji*; Akahane, Keiichi*; Okuda, Yasuo*; Sato, Kaoru; Takahashi, Fumiaki; Yoshitake, Takayasu*; Hasegawa, Takayuki*; et al.

no journal, , 

Many of the CT devices are in Japan. It is guessed that exposure doses of Japanese derived from CT scans are higher than others. Thus, it is needed to properly manage scan conditions and exposure doses of individual patients. JAEA developed WAZA-ARI under the collaboration research project with the National Institute of Radiological Sciences (NIRS) and the Oita University of Nursing and Health Sciences. Practical use of new version WAZA-ARI named WAZA-ARIv2 began on January 30, 2015 at the web server in NIRS. In WAZA-ARIv2, users can calculate patients doses by using only standard condition (120 kV) of X-tube voltage. In recent years, CT scans at low tube voltage against pediatric patients with high radiosensitivity are increasing. In this study, spectrum of X-ray derived from CT scan at low tube voltage was examined, and was defined in "usrsors.f" file of PHITS. We reported the characteristics of X-ray and organ doses derived from CT scan at low tube voltage (80 kV).

Oral presentation

Calculating dose distribution from diagnostic CT depending on age and physique size of patients; Development of dose assessment web - system WAZA-ARI

Ono, Koji*; Koba, Yusuke*; Matsumoto, Shinnosuke*; Nakada, Yoshihiro*; Okuda, Yasuo*; Akahane, Keiichi*; Sato, Kaoru; Takahashi, Fumiaki; Yoshitake, Takayasu*; Hasegawa, Takayuki*; et al.

no journal, , 

In medical treatment, CT scan is useful diagnostic method. On the other hand, exposure doses derived from CT scans are dependent on body sizes of patients. Therefore, consideration of body sizes is essential for accurate dose assessment of individual patients. JAEA developed the CT dose calculator, WAZA-ARIv2 under the collaboration research project with the National Institute of Radiological Sciences and the Oita University of Nursing and Health Sciences. WAZA-ARIv2 enable users to accurately calculate exposure doses of patients with sexes, ages (0y, 1y, 5y, 10y, 15y and adult) and fatness (small, large and extra-large body sizes). In the future, we will be plans to add the dose calculation functions corresponding to the scan conditions at low tube voltage and multi-detector row (more 80) CT devices to WAZA-ARIv2. We reported the system and future plans of WAZA-ARIv2 corresponding to dose calculation of patients with various body sizes.

Oral presentation

Analysis of organ doses by CT diagnosis for patients of optional physique by using voxel phantoms

Sato, Kaoru; Takahashi, Fumiaki; Koba, Yusuke*; Ono, Koji*; Yoshitake, Takayasu*; Hasegawa, Takayuki*; Katsunuma, Yasushi*; Kasahara, Tetsuji*; Okuda, Yasuo*; Nakada, Yoshihiro*; et al.

no journal, , 

WAZA-ARIv2 is developed as the web-based open system for CT dose calculator under joint research of JAEA, NIRS (now, QST) and Oita University of Nursing and Health Sciences. WAZA-ARIv2 can provide organ doses under consideration of the body physiques (BMI = 18, 22, 28, 37) of patients with average height of adult Japanese by using voxel phantoms developed by JAEA. In this study, we analyzed the relationship between variations of organ doses and body indices. It was found that effects of weight variations on organ doses were larger than those of height variations. Generally, thickness of the subcutaneous soft tissues is easily changed by variations of weight rather than those of height. This fact may cause the differences in variations of organ doses between weight and height.